HBHM7 laboratory centrifuge
This benchtop laboratory centrifuge is fitted with a fixed-angle rotor for 8 tubes of 8 to 15 ml.
- 4000 rpm: maximum relative centrifugal force of 1980 x g.
- 1 to 99 minute timer with countdown and automatic stop.
- Brushless motor: noise level below 65 dB(A).
- Compact format: 265 x 305 x 205 mm, 6 kg.
- 1-year warranty on the machine.
Microprocessor control, control keys with digital display of speed and time, 220 V power supply.
CE Certification
Delivery all over Europe
Free shipping for orders over 500€ HT
This low-speed benchtop laboratory centrifuge is fitted with a fixed-angle rotor for 8 tubes of 8 to 15 ml. It reaches 4000 rpm (1980 x g) with a brushless motor and a timer adjustable up to 99 minutes.
A compact centrifuge for 8 to 15 ml tubes
Principle. Centrifugation separates, purifies and concentrates the particles of a liquid by sedimentation. According to the manufacturer's manual, this type of device is used in clinical medicine, biochemistry, genetic engineering and radioimmunology, in research institutes and hospitals.
Rotor. The fixed-angle rotor holds 8 tubes of 8 to 15 ml, placed in even numbers and symmetrically. It is fitted to the machine on delivery.
Footprint. At 265 x 305 x 205 mm and 6 kg, it sits on a flat, sturdy bench. Allow 30 cm of clearance around the unit while it is running.
Technical specifications
Centrifugation
- Maximum speed: 4000 rpm
- Maximum relative centrifugal force: 1980 x g
- Fixed-angle rotor, 8 x 15 ml
- Tubes of 8 to 15 ml
- Adjustable time from 1 to 99 minutes, countdown
- Speed accuracy: ± 50 rpm
Control and motor
- Microprocessor control
- Control keys and digital display of speed and time
- PWM speed regulation
- Brushless DC motor, no carbon dust
- Vibration damper with automatic balancing
- Automatic stop at the end of the countdown
Installation
- Power supply: 220 V, 50/60 Hz, 2 A
- Dimensions: W 265 x D 305 x H 205 mm
- Net weight: 6 kg
- Noise level: < 65 dB(A)
- Operating temperature: 10 to 35 °C
- Relative humidity: 85 % maximum
- CE marking
Safety precautions
- Place the tubes in even numbers and symmetrically, to avoid vibration and imbalance.
- Use only the rotor and accessories intended for the machine, and never exceed the maximum speed of the rotor.
- Do not open the lid while the rotor is spinning and do not slow the rotor down by hand.
- Plug the unit into an earthed socket. Do not centrifuge flammable or explosive materials.
- Handle potentially infectious samples according to laboratory procedures.
Warranty
The manufacturer states a 1-year warranty on the machine. It does not cover failures caused by incorrect installation or use, unauthorised repair, or the use of a rotor not intended for the unit.